High Voltage X-Ray Generator for Mobile DR System
DMP-300

High Voltage X-Ray Generator for Mobile DR System
  • 50kW output reduces exposure time for higher-quality images
  • High-capacity 3U-NCM Li-based battery extends operation time
  • 12/24/105 VDC auxiliary power simplifies system integration
  • Digital control circuit enhances performance and accuracy
  • Built-in energy storage system extends the battery life

Product Description

  • Powerful Heart for Mobile DR Systems

    The DMP-300 X-ray Generator is designed for medical mobile DR systems. With a maximum power of 50 kW and high-frequency output of 450 kHz, the DMP-300 can effectively improve DR system performance. Its compact 3U-NCM Li-based battery and built-in energy storage pack lengthen operation times, which extends battery life. The DMP-300 is the most powerful heart for medical DR mobile systems.

    Powerful Heart for Mobile DR Systems

Product Spec

    • 32kW

      • Input Voltage 40 - 60 VDC, for Generator, 100 VAC – 240 VAC 1Ф, for Battery Charger
      • Input Current Range 15 A - 10 A, for Battery Charger
      • Input Frequency 50 Hz / 60 Hz, for Battery Charger
      • kV Range 40 - 150 kV, 1 kV / Step
      • kV Accuracy ± (5% of preset value + 1 kV)
      • Rise Time < 1.5 ms (10% - 90%)
      • mA Range 10 mA - 630 mA, R’20
      • mA Accuracy +/- (5% of preset value + 1 mA)
      • ms Range 1 ms - 10000 ms, R’20
      • ms Accuracy ± (10% of preset value + 1 ms)
      • mAs Range 0.1 mAs - 630 mAs @40kV, R’20
      • mAs Accuracy ± (5% of preset value + 0.2 mAs)
      • Max. Output Power 320 mA / 100 kV / 160 ms
      • Battery Charger 52 VDC / 19A
      • Battery Pack NA
      • Energy Storage Pack 126 mF
      • External Output Voltage 12 VDC / 14A, 24 VDC / 10A, 105 VDC / 5A
      • Motor Starter Dual Speed
      • Support Peripherals AEC / DAP, Optional
      • Dimension (L x W x H) High-Voltage Generator: 500 mm x 352 mm x 305 mm, Battery Pack: 460 mm x 430 mm x 120 mm, Energy Storage Pack: 500 mm x 352 mm x 150 mm
      • Weight High-Voltage Generator: 22.0 kg, Battery Pack: 28.5 kg, Energy Storage Pack: 18.5 kg
      • Safety IEC 60601-1 2nd edition, IEC 60601-1 3.1rd edition and IEC 60601-1 3.2rd edition, IEC 60601-2-54
      • Electromagnetic Compatibility IEC 60601-1-2 4ᵗʰ edition compliance
    • 40kW

      • Input Voltage 40 - 60 VDC, for Generator, 100 VAC – 240 VAC 1Ф, for Battery Charger
      • Input Current Range 15 A - 10 A, for Battery Charger
      • Input Frequency 50 Hz / 60 Hz, for Battery Charger
      • kV Range 40 - 150 kV, 1 kV / Step
      • kV Accuracy ± (5% of preset value + 1 kV)
      • Rise Time < 1.5 ms (10% - 90%)
      • mA Range 10 mA - 630 mA, R’20
      • mA Accuracy +/- (5% of preset value + 1 mA)
      • ms Range 1 ms - 10000 ms, R’20
      • ms Accuracy ± (10% of preset value + 1 ms)
      • mAs Range 0.1 mAs - 630 mAs @40kV, R’20
      • mAs Accuracy ± (5% of preset value + 0.2 mAs)
      • Max. Output Power 400 mA / 100 kV / 125 ms
      • Battery Charger 52 VDC / 19A
      • Battery Pack NA
      • Energy Storage Pack 126 mF
      • External Output Voltage 12 VDC / 14A, 24 VDC / 10A, 105 VDC / 5A
      • Motor Starter Dual Speed
      • Support Peripherals AEC / DAP, Optional
      • Dimension (L x W x H) High-Voltage Generator: 500 mm x 352 mm x 305 mm, Battery Pack: 460 mm x 430 mm x 120 mm, Energy Storage Pack: 500 mm x 352 mm x 150 mm
      • Weight High-Voltage Generator: 22.0 kg, Battery Pack: 28.5 kg, Energy Storage Pack: 18.5 kg
      • Safety IEC 60601-1 2nd edition, IEC 60601-1 3.1rd edition and IEC 60601-1 3.2rd edition, IEC 60601-2-54
      • Electromagnetic Compatibility IEC 60601-1-2 4ᵗʰ edition compliance
    • 50kW

      • Input Voltage 40 - 60 VDC, for Generator, 100 VAC – 240 VAC 1Ф, for Battery Charger
      • Input Current Range 15 A - 10 A, for Battery Charger
      • Input Frequency 50 Hz / 60 Hz, for Battery Charger
      • kV Range 40 - 150 kV, 1 kV / Step
      • kV Accuracy ± (5% of preset value + 1 kV)
      • Rise Time < 1.5 ms (10% - 90%)
      • mA Range 10 mA - 630 mA, R’20
      • mA Accuracy +/- (5% of preset value + 1 mA)
      • ms Range 1 ms - 10000 ms, R’20
      • ms Accuracy ± (10% of preset value + 1 ms)
      • mAs Range 0.1 mAs - 630 mAs @40kV, R’20
      • mAs Accuracy ± (5% of preset value + 0.2 mAs)
      • Max. Output Power 500 mA / 100 kV / 100 ms, 560 mA / 100 kV / 20 ms
      • Battery Charger 52 VDC / 19A
      • Battery Pack 3U-NCM Battery (48V, 50Ah)
      • Energy Storage Pack 126 mF
      • External Output Voltage 12 VDC / 14A, 24 VDC / 10A, 105 VDC / 5A
      • Motor Starter Dual Speed
      • Support Peripherals AEC / DAP, Optional
      • Dimension (L x W x H) High-Voltage Generator: 500 mm x 352 mm x 305 mm, Battery Pack: 460 mm x 430 mm x 120 mm, Energy Storage Pack: 500 mm x 352 mm x 150 mm
      • Weight High-Voltage Generator: 22.0 kg, Battery Pack: 28.5 kg, Energy Storage Pack: 18.5 kg
      • Safety IEC 60601-1 2nd edition, IEC 60601-1 3.1rd edition and IEC 60601-1 3.2rd edition, IEC 60601-2-54
      • Electromagnetic Compatibility IEC 60601-1-2 4ᵗʰ edition compliance
  • Document Download

Sorry, your browser is not supported.

We recommend using the latest versions of Chrome, Firefox, Safari or Internet Explorer